AquaSense
Product Information
Category: Water Quality Monitoring SystemsSwimming pools and spas use chlorine as a disinfectant and so use an analyzer to control the amount of chlorine that gets dosed. The AquaSense Swimming Pool Controller and Spa Controller measures the pool chlorine levels and the pH of the pool and then controls the chlorine and pH levels by controlling the chemical dosing. The AquaSense offers bufferless and reagentless operation and is suitable for commercial, municipal and community swimming pools.
The AquaSense has been designed to three criteria:
- Improved Safety – better sensors lead to better process control which leads to less variation in chlorine residuals even with highly variable bathing load.
- Improved Control – better process control leads to reduced chemical usage, lower costs and an improved bathing experience.
- Reduced Costs – lower chemical costs, less expensive controllers, inverter control leading to hugely reduced electrical usage costs are just a few of the ways that the AquaSense can save you money which can pay for a new controller in just a few months.
Key Benefits
- Inverter control for massive electricity and CO2 savings
- Stable and reliable residual chlorine and pH measurement and control
- Low purchase cost
- Low cost of ownership
- SMS text alarms
- Remote access via Internet
- Suitable for fresh water, salt water and outdoor pools with cyanuric acid
- Private label option for re-sellers
- Other inputs to data log and alarms
Related Products
ORPSense
Key Benefits
The ORPSense range of ORP Meters from Pi utilize the very latest and best ORP sensors available in the world today for measuring the online Redox potential of any aqueous solution. They are platinum ball based sensors with integral reference electrodes which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs. Online ORP meters and ORP controllers are one of the most common analyzers in use today in water treatment and process plants and yet online ORP meters cause continual problems for their operators. What is needed is a stable, reliable, online ORP meter for a reasonable cost. That is exactly what you get with the ORPSense and the ORPSense Automatic Calibrator. The ORPSense sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and control options. With the ORPSense range of ORP meters, you get everything that you need – and nothing that you don’t.-
Stable and reliable ORP meter
On board diagnostics
Low purchase cost
Long life ORP sensors
Remote access and SMS text alarms
PID and other process controls
was last modified: April 16th, 2019
PC-110 pH/ORP Panel Meter
Compact and Pragmatic
The PC-110 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installaion. The PC-100 features for sample monitoring and the PC-110 offers one relay output to sufficiently activate your process system.Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics processFeatures
- 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
- Sensor slope performance diagnosis & error message
- User-friendly operation
- Automatic temperature compensation
- Compatible with Pt-1000 and NTC 30K temperature probe
- Isolated current output DC 0/4~20mA
- Gradually continuous sample measurements average function to enhance stability
- PC-110 offers one relay contact output, one set point with programmable hysteresis function
was last modified: March 23rd, 2019
FluoriSense
Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.- Measuring method: ISE (Ion Specific Electrode)
- Measure range: 0.02 ppm saturation
- Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
- Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
- Electrode resistance: less than 50 MΩ
- Reproducibility: ±2%
- Cable length: 100cm
- Calibration: Manual using test kit
- No reagent required
was last modified: April 16th, 2019
S272CD Online Process pH Sensor
Product Description
The S272CD online process pH sensor delivers reliable online monitoring for in-line or submersion installation configuration. This sensor is designed to extend sensor lifetime with double-junction technology. Minimal maintenance required due to flat glass measurement surface. A versatile sensor for moderate and multi-purpose applications.- Reliable performance in demanding applications: Liquid flow naturally cleans the flat pH measurement surface
- Extended sensor lifetime: Double junction technology extends sensor lifetime by preventing reference contamination
- Versatile design for many applications: 3/4″ NPT threads on both ends for submersion or in-line mounting
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
was last modified: April 25th, 2019
pH3400 Research Grade Glass pH Electrode
Product Description
In laboratory environments such as medical, biological, and materials science research groups, samples and test conditions are constantly changing, but accuracy is always critical. The pH3400 is a highly versatile glass combination pH electrode, specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals allow testing of low ionic samples. Safely measure samples containing heavy metals, TRIS buffer, or proteins thanks to the double junction reference design, which prevents fouling. Even test highly reactive chemicals: with a glass body, the pH3400 is inert to a wide range of chemical reactions.- Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
- Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
- Safe for use with reactive chemicals: Glass bodies are inert to many chemical reactions
- Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
- Ready for wet or corrosive environments: BNC boot protects meter connection
was last modified: April 25th, 2019
pH2500 Flat Surface Glass pH Electrode
Product Description
Surfaces like paper, leather, electrophoresis gels and agar plates may be difficult to measure with traditional pH glass bulbs due to concerns about breakage. A flat electrode like our pH2500, is ideally suited for these types of pH measurements as well as measurements of suspended sludges and slurries. In addition to its specially designed measurement surface, the pH2500 features double junction construction, which prevents contamination and allows testing of samples containing heavy metals or proteins.- Perfect for gels and slurries: Flat electrode measurement surface designed for testing special sample types
- Accurate measurements across full pH scale (0-14)
- Highly adaptable: Compatible with any pH meter accepting BNC
- Low maintenance: Gel-filled electrode reference design with double junction to prevent contamination
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
was last modified: April 25th, 2019
BioSense
Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.- Legionella control
- Automatic Biocide control
- Can be combined with other sensors
- No maintenance
- Cooling towers and any water circuit
- Seawater option Reduced chemical costs Up to 10 Bar
was last modified: April 16th, 2019
ORP2000 Extended Life ORP Sensor
Product Description
When measuring samples such as wastewaster that may contain proteins, heavy metals, or other contaminants, it is important to use an ORP sensor (REDOX sensor) designed to withstand unpredictable chemical environments. The ORP2000 features double junction reference protection, which prevents contamination by sample components that interact with silver (Ag). The durable Ultem® body ensures extensive chemical compatibility, making the ORP2000 a highly versatile analytical tool.- Virtually unbreakable with durable Ultem® body construction and recessed protected glass
- Reliable and accurate ORP / REDOX measurements
- No refilling or maintenance required with sealed gel-filled design
- Instantly ready for use and shipped in storage bottle for long shelf life – guaranteed for one year
- One year limited warranty
was last modified: April 25th, 2019
UV254Sense
Key Benefits
Standard Features
was last modified: April 16th, 2019
HaloSense Zero
Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).- Low purchase cost
- Low cost of ownership
- Reduced pH dependency (largely pH independent)
- Stable and reliable
- Bufferless
- Reagentless
was last modified: April 16th, 2019