Ternary Liquid Analysers – 9500 Series
Product Information
Category: Water Quality Monitoring SystemsProduct Description
The key issue when gauging two components in a liquid is that the speed at which sound travels will be different for either (at the same temperature). This makes it difficult to determine whether the concentration of liquid one or two is changing. However, the 9500 series analysers are able to determine both concentrations by measuring the speed of sound and conductivity, or otherwise the speed of sound and the density of the liquid, at the same time.
Key Benefits
- Low cost of ownership
- High degree of accuracy and reproducibility
- Completely maintenance free
- No reagents required
- On site with no moving parts
- High-end software technology that is easy to operate
- Colour display
- Data logging
- Supports various communication protocols, including Modbus, Profibus & HART
Related Products
HaloSense Zero
Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).- Low purchase cost
- Low cost of ownership
- Reduced pH dependency (largely pH independent)
- Stable and reliable
- Bufferless
- Reagentless
was last modified: April 16th, 2019
SG-2110-RS Intelligent Specific Gravity Transmitter
Applications
Electronics industry Chemical industryFeatures
- Waterproof and dustproof design
- 96 x 96mm microprocessor Specific Gravity/Baumé/Salinity/ Concentration transmitter
- Measuring unit: SG/°Bé/ ppt/ %
- User-friendly operation with text and graphic illustration, clear signs and easy to understand
- Measuring value can be selected for figure or chart display
- Trace mode can display historical measured value curve from 3-minute to 4-week program
- Equipped with logbook function
- Large LCM display with auto-sense backlight and contrast setting function
- Built-in Specific gravity - Concentration conversion table for setting, up to 10 points
- Cell constant, Pure water, Known solution— 3 types calibration
- Simultaneous display of measurement value and temperature
- Automatic temperature compensation for setting
- Equipped with one analog output DC 0/4~20mA, Max.500Ω and RS-485 interface
- Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis
- With password and multi-key design, enhanced security protection
- LED indicated alarm
- IP 65 (NEMA 4X)
Specific Gravity Sensor
Load Cell & plummet principle High accuracy & long lifetime of reliability Wide range measurement Anti-acid gas design was last modified: March 23rd, 2019
PC-110 pH/ORP Panel Meter
Compact and Pragmatic
The PC-110 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installaion. The PC-100 features for sample monitoring and the PC-110 offers one relay output to sufficiently activate your process system.Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics processFeatures
- 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
- Sensor slope performance diagnosis & error message
- User-friendly operation
- Automatic temperature compensation
- Compatible with Pt-1000 and NTC 30K temperature probe
- Isolated current output DC 0/4~20mA
- Gradually continuous sample measurements average function to enhance stability
- PC-110 offers one relay contact output, one set point with programmable hysteresis function
was last modified: March 23rd, 2019
StreamerSense
Key Benefits
- Immediate response to process changes in coagulation treatment – coagulation monitor
- Maintain high quality finished water through improved coagulation control –coagulation controller
- Reduce coagulant/polymer costs – coagulant analyzer
- Automate dosing coagulant/polymer dosing using the streaming current monitor –coagulant control
- Ensure coagulation reliability – coagulant analyzer
- Improve operator efficiency – coagulant analyzer
- Improve filter performance and coagulation treatment – coagulation controller
- Monitor your coagulation control process – coagulation monitor
Streaming Current Monitors Standard Features
- Patented sensor design
- Quick replacement probe and piston
- Self-diagnostic sensor
- High-volume flow minimizes sensor fouling
- Removes electronics from harsh environments
- Corrosion-free Nema 4x enclosure (IP65)
- Optional computer interface
- Spare probe cartridge and piston included
- Auxiliary input signals
was last modified: April 16th, 2019
pH2000 Extended Life Laboratory Plastic pH Sensor
Product Description
Applications such as environmental and wastewater sampling involve some uncertainty about what samples may contain. When dealing with unknown or unpredictable sample types, you need a durable pH probe you can trust to deliver accurate measurements regardless of the contaminants you encounter. The pH2000 has a double junction reference design to prevent reference fouling by heavy metals and other sample contaminants. When you travel to remote sites to collect data, it is especially important that obtaining the measurements you need is hassle free. The pH2000 features an Ultem® body and a booted meter connection for durability in the field. The sealed reference design requires no maintenance. Compatible with any meter accepting a BNC connector.- Durable and low maintenance: Ultem® body construction, reinforced meter connection, and sealed reference design
- Great for testing unknown sample types: Double junction reference protection prevents reference cell contamination
- Accurate measurements across full pH scale (0-14)
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- Compatible with any meter accepting a BNC connector
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
was last modified: April 25th, 2019
PC-100 pH/ORP Panel Meter
The PC-100 pH/ORP monitors utilize microprocessor technology to provide you enhanced capabilities with economical price. The compact design fits in small space installation. The PC-100 features for sample monitoring.
Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics processFeatures
- 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
- Sensor slope performance diagnosis & error message
- User-friendly operation
- Automatic temperature compensation
- Compatible with Pt-1000 and NTC 30K temperature probe
- Isolated current output DC 0/4~20mA
- Gradually continuous sample measurements average function to enhance stability
was last modified: March 23rd, 2019
TurbSense®
Key Benefits
The TurbSense® online turbidity meters are available with different controllers giving you the same great performance with different communication, display, and control options. With the TurbSense® range of online turbidity meters, you get everything that you need – and nothing that you don’t, without sacrificing the quality of the measurement. The online turbidity meters from Pi are now in use around the world providing trouble free, easy to use solutions to a range of online turbidity monitoring and control.- Autoclean solid state optical sensor – no moving parts
- Single point calibration – very easy to use
- Stable and reliable – excellent process control
- Suitable for all potable, waste and process waters between 0 NTU and 1000 NTU
- ‘Maintenance free’ – low cost of ownership
- No ‘zero’ required – improved accuracy at the low end
- Up to 1 year between calibration – very little drift
- Up to 10 bar – for inline operation
- 0.001 resolution
- Automatic debubbling and bubble removal solutions – no interference from bubbles
was last modified: April 16th, 2019
SoliSense®
Key Benefits
- From 2 NTU to 8% Solids
- Displays in NTU, mg/l, g/l or % solids – flexible
- Auto-clean optical sensor – months without maintenance
- Stable and reliable – excellent process control
- Suitable for all potable, waste and process waters
- Up to 12 months between maintenance
- Up to 12 months between calibration
- Less spares – more commonality across a single or multiple sites
- No requirement to know the range prior to specifying – easier purchasing
- One online suspended solids analyzer can be:
- Online mlss meter
- Online tss meter
- Online total suspended solids meter
- Online effluent monitor
- Online inlet monitor
- Online ‘in process’ suspended solids analyzer
was last modified: April 16th, 2019
pH2100 Flat Tip Plastic pH Electrode
Product Description
Agar plates, skin, and electrophoresis gels are all surfaces that may be difficult to measure with a typical pH glass bulb due to concerns about breakage. To facilitate these and other surface measurements, we created the pH2100 flat tip pH electrode. It has a rugged flat measurement surface, which breaks less easily when it comes in contact with hard materials. This makes it a great choice for measuring slurries, sludges, and viscous samples as well as those containing suspended solids.- Ideal for surface measurements and slurries: rugged flat measurement tip resists breakage
- Great for testing unknown sample types: double junction electrode reference design prevents contamination
- Durable and Versatile: Ultem® body offers enhanced chemical compatibility and booted BNC protects meter connection
- No maintenance required: sealed gel filled reference design
- One year limited warranty: We stand by our products with the Sensorex guarantee
was last modified: April 25th, 2019
FluoriSense
Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.- Measuring method: ISE (Ion Specific Electrode)
- Measure range: 0.02 ppm saturation
- Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
- Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
- Electrode resistance: less than 50 MΩ
- Reproducibility: ±2%
- Cable length: 100cm
- Calibration: Manual using test kit
- No reagent required
was last modified: April 16th, 2019