Category: Water Quality Monitoring SystemsProduct Description
The EX90-series battery powered, insertion electromagnetic flow meter is designed for use with conductive fluids in 4”–12” pipe. The EX90’s stainless steel body allows the meter to operate in a wide range of temperatures, pressure, and corrosive or dirty environments.
The EX90 is highly suitable for difficult applications. With no moving parts, these meters can be used in “dirty water” applications where debris would foul a mechanical meter. If the EX90 meter is used with a programmable controller, the output signal can be fed direct, with no other conditioning required.
Rate and total units can be set via the front panel touch key pad by the user. Bidirectional flow is standard with totals available in forward, reverse, net, batch forward and batch reverse.
The EX90 is battery powered and an output cable is available for transmitting the pulse signal to remote devices. The EX90 includes a Seametrics saddle which has been designed to accommodate a wide range of pipe sizes and types while ensuring correct placement in the pipe. In addition, an optional internal data logger allows local storage of flow history.
Related Products
pH2400 Extended Life Glass pH Electrode
Product Description
Environmental, wastewater, and other sampling applications may expose electrodes to unknown contaminants. Over time, exposure to contaminants such as heavy metals and reactive chemicals, will take a toll on a sensor’s functional components. The best sensors for these types of applications are built to safely handle contaminants to maximize working lifetime. Our pH2400 is a glass electrode with double junction reference design to prevent fouling by sample contaminants that interact with Silver (Ag). The refillable reference junction allows users to replace the liquid fill solution as it becomes depleted or contaminated, instead of replacing the whole sensor.- Accurate measurements across full pH scale (0-14)
- Maximum chemical compatibility: glass electrode bodies are inert to most reactions
- Extended lifetime: Refillable reference junction allows sensor maintenance, saving replacement costs
- Great for wet or corrosive environments: BNC boot protects meter connection
- Compatible with any meter accepting BNC
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
pH2000 Extended Life Laboratory Plastic pH Sensor
Product Description
Applications such as environmental and wastewater sampling involve some uncertainty about what samples may contain. When dealing with unknown or unpredictable sample types, you need a durable pH probe you can trust to deliver accurate measurements regardless of the contaminants you encounter. The pH2000 has a double junction reference design to prevent reference fouling by heavy metals and other sample contaminants. When you travel to remote sites to collect data, it is especially important that obtaining the measurements you need is hassle free. The pH2000 features an Ultem® body and a booted meter connection for durability in the field. The sealed reference design requires no maintenance. Compatible with any meter accepting a BNC connector.- Durable and low maintenance: Ultem® body construction, reinforced meter connection, and sealed reference design
- Great for testing unknown sample types: Double junction reference protection prevents reference cell contamination
- Accurate measurements across full pH scale (0-14)
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- Compatible with any meter accepting a BNC connector
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
S272CD Online Process pH Sensor
Product Description
The S272CD online process pH sensor delivers reliable online monitoring for in-line or submersion installation configuration. This sensor is designed to extend sensor lifetime with double-junction technology. Minimal maintenance required due to flat glass measurement surface. A versatile sensor for moderate and multi-purpose applications.- Reliable performance in demanding applications: Liquid flow naturally cleans the flat pH measurement surface
- Extended sensor lifetime: Double junction technology extends sensor lifetime by preventing reference contamination
- Versatile design for many applications: 3/4″ NPT threads on both ends for submersion or in-line mounting
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
FluoriSense
Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.- Measuring method: ISE (Ion Specific Electrode)
- Measure range: 0.02 ppm saturation
- Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
- Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
- Electrode resistance: less than 50 MΩ
- Reproducibility: ±2%
- Cable length: 100cm
- Calibration: Manual using test kit
- No reagent required
HaloSense Zero
Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).- Low purchase cost
- Low cost of ownership
- Reduced pH dependency (largely pH independent)
- Stable and reliable
- Bufferless
- Reagentless
UV254Sense
Key Benefits
Standard Features
pH2500 Flat Surface Glass pH Electrode
Product Description
Surfaces like paper, leather, electrophoresis gels and agar plates may be difficult to measure with traditional pH glass bulbs due to concerns about breakage. A flat electrode like our pH2500, is ideally suited for these types of pH measurements as well as measurements of suspended sludges and slurries. In addition to its specially designed measurement surface, the pH2500 features double junction construction, which prevents contamination and allows testing of samples containing heavy metals or proteins.- Perfect for gels and slurries: Flat electrode measurement surface designed for testing special sample types
- Accurate measurements across full pH scale (0-14)
- Highly adaptable: Compatible with any pH meter accepting BNC
- Low maintenance: Gel-filled electrode reference design with double junction to prevent contamination
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
SoliSense®
Key Benefits
- From 2 NTU to 8% Solids
- Displays in NTU, mg/l, g/l or % solids – flexible
- Auto-clean optical sensor – months without maintenance
- Stable and reliable – excellent process control
- Suitable for all potable, waste and process waters
- Up to 12 months between maintenance
- Up to 12 months between calibration
- Less spares – more commonality across a single or multiple sites
- No requirement to know the range prior to specifying – easier purchasing
- One online suspended solids analyzer can be:
- Online mlss meter
- Online tss meter
- Online total suspended solids meter
- Online effluent monitor
- Online inlet monitor
- Online ‘in process’ suspended solids analyzer
StreamerSense
Key Benefits
- Immediate response to process changes in coagulation treatment – coagulation monitor
- Maintain high quality finished water through improved coagulation control –coagulation controller
- Reduce coagulant/polymer costs – coagulant analyzer
- Automate dosing coagulant/polymer dosing using the streaming current monitor –coagulant control
- Ensure coagulation reliability – coagulant analyzer
- Improve operator efficiency – coagulant analyzer
- Improve filter performance and coagulation treatment – coagulation controller
- Monitor your coagulation control process – coagulation monitor
Streaming Current Monitors Standard Features
- Patented sensor design
- Quick replacement probe and piston
- Self-diagnostic sensor
- High-volume flow minimizes sensor fouling
- Removes electronics from harsh environments
- Corrosion-free Nema 4x enclosure (IP65)
- Optional computer interface
- Spare probe cartridge and piston included
- Auxiliary input signals
AquaSense
- Improved Safety – better sensors lead to better process control which leads to less variation in chlorine residuals even with highly variable bathing load.
- Improved Control – better process control leads to reduced chemical usage, lower costs and an improved bathing experience.
- Reduced Costs – lower chemical costs, less expensive controllers, inverter control leading to hugely reduced electrical usage costs are just a few of the ways that the AquaSense can save you money which can pay for a new controller in just a few months.
Key Benefits
- Inverter control for massive electricity and CO2 savings
- Stable and reliable residual chlorine and pH measurement and control
- Low purchase cost
- Low cost of ownership
- SMS text alarms
- Remote access via Internet
- Suitable for fresh water, salt water and outdoor pools with cyanuric acid
- Private label option for re-sellers
- Other inputs to data log and alarms