Navigation

pH1400 Light Duty Glass pH Electrode

‹Return to Previous Page

Related Products

Quick View

ORP1000 Polycarbonate Laboratory ORP Sensor

Product Description
The ORP1000 is a durable and easy to use ORP sensor. Great for outdoor applications, such as monitoring swimming pool chlorine, this probe has built in protection for the ORP sensor surface. Use the ORP1000 with any ORP meter accepting a BNC connector.
  • Very fast response time: Platinum measurement surface for fast response time and stable readings
  • No maintenance required: Sealed reference design requires no refilling
  • Durable construction: Polycarbonate body is built for frequent lab or field use
  • Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
  • One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Quick View

OzoSense

The OzoSense Online Dissolved Ozone Monitor from Pi for the measurement of the ozone concentration in water, is designed to be simple to install and operate, and offers unrivalled stability, accuracy and precision, whilst offering excellent value for money. The OzoSense range of online dissolved ozone analyzers and dissolved ozone monitors utilize the very latest and best ozone sensors available in the world today. There are two sensors in the OzoSense range. The first is a membraned device which is insensitive to changing pH, uses no reagents, is extremely stable, and has reduced maintenance and reduced whole life costs. The second is a non membraned three electrode sensor, that can operate at higher temperatures and pressures.
Key Benefits
  • Stable and reliable – excellent ozone process control – ozone controllers
  • Suitable for all potable, process and salt waters – ozone monitor – ozone analyzer
  • Up to 6 months between maintenance
  • Up to 3 months between calibration
  • Does not respond to residual chlorine (OzoSense M)
  • Resistant to detergents in the water
  • Up to 70°C (OzoSense NM)
  • Onboard PID controls – dissolved ozone Controller
  • Onboard data logging and graphing capability
  • Onboard comms such as TCP/IP, Modbus, Profibus and more.
Quick View

SG-2110-RS Intelligent Specific Gravity Transmitter

Applications
Electronics industry Chemical industry
Features
  1. Waterproof and dustproof design
  2. 96 x 96mm microprocessor Specific Gravity/Baumé/Salinity/ Concentration transmitter
  3. Measuring unit: SG/°Bé/ ppt/ %
  4. User-friendly operation with text and graphic illustration, clear signs and easy to understand
  5. Measuring value can be selected for figure or chart display
  6. Trace mode can display historical measured value curve from 3-minute to 4-week program
  7. Equipped with logbook function
  8. Large LCM display with auto-sense backlight and contrast setting function
  9. Built-in Specific gravity - Concentration conversion table for setting, up to 10 points
  10. Cell constant, Pure water, Known solution— 3 types calibration
  11. Simultaneous display of measurement value and temperature
  12. Automatic temperature compensation for setting
  13. Equipped with one analog output DC 0/4~20mA, Max.500Ω and RS-485 interface
  14. Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact outputs with programmable set-points and hysteresis
  15. With password and multi-key design, enhanced security protection
  16. LED indicated alarm
  17. IP 65 (NEMA 4X)
Specific Gravity Sensor
Load Cell & plummet principle High accuracy & long lifetime of reliability Wide range measurement Anti-acid gas design
Quick View

BioSense

Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.
  • Legionella control
  • Automatic Biocide control
  • Can be combined with other sensors
  • No maintenance
  • Cooling towers and any water circuit
  • Seawater option Reduced chemical costs Up to 10 Bar
Quick View

AquaSense

Swimming pools and spas use chlorine as a disinfectant and so use an analyzer to control the amount of chlorine that gets dosed. The AquaSense Swimming Pool Controller and Spa Controller measures the pool chlorine levels and the pH of the pool and then controls the chlorine and pH levels by controlling the chemical dosing. The AquaSense offers bufferless and reagentless operation and is suitable for commercial, municipal and community swimming pools. The AquaSense has been designed to three criteria:
  • Improved Safety – better sensors lead to better process control which leads to less variation in chlorine residuals even with highly variable bathing load.
  • Improved Control – better process control leads to reduced chemical usage, lower costs and an improved bathing experience.
  • Reduced Costs – lower chemical costs, less expensive controllers, inverter control leading to hugely reduced electrical usage costs are just a few of the ways that the AquaSense can save you money which can pay for a new controller in just a few months.
Key Benefits
  • Inverter control for massive electricity and CO2 savings
  • Stable and reliable residual chlorine and pH measurement and control
  • Low purchase cost
  • Low cost of ownership
  • SMS text alarms
  • Remote access via Internet
  • Suitable for fresh water, salt water and outdoor pools with cyanuric acid
  • Private label option for re-sellers
  • Other inputs to data log and alarms
Quick View

HaloSense Zero

Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).
  • Low purchase cost
  • Low cost of ownership
  • Reduced pH dependency (largely pH independent)
  • Stable and reliable
  • Bufferless
  • Reagentless
Quick View

PC-3100 Series Microprocessor pH/ORP Transmitter

Robust protection and precise integration

The PC-3100 series pH/ORP transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions.

Applications
Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage process
Features
  1. pH, ORP, Temperature measurement
  2. IP 65 waterproof and dustproof design
  3. Back-lit LCD with ON/OFF/Auto programmable illumination
  4. Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature
  5. Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function
  6. Automatic temperature compensation
  7. Gradually continuous sample measurements average function to enhance stability
  8. Wash function with programmable time-interval control
  9. LED indication alarm or wash status signal
  10. Password protection
  11. PC-3100RS with one analog output and one RS-485 interface
Quick View

ORP3000 Research Grade ORP Electrode

Product Description
In harsh laboratory or field conditions, where heat, moisture, or corrosive chemicals may damage equipment, ORP electrode durability is key. The ORP3000 is durable, research grade ORP electrode. All the functional components – the ORP measurement surface, the meter connection, and the cable connection – are reinforced with protective elements. Durable Ultem® body construction provides extensive chemical compatibility and withstands temperatures up to 100°C.
  • Virtually unbreakable: removable guard protects ORP measurement surface and strain relief prevents damage to cable connection
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • No maintenance required: Sealed gel reference design does not require users to refill solution
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ready for wet or corrosive environments: BNC boot protects meter connection
Quick View

pH3000 Research-Grade Plastic pH Sensor (Refillable)

Product Description
When accuracy and repeatability are critical, such as in pharmaceutical or drinking water applications, the ideal pH electrode will quickly deliver stable measurements. The pH3000 is a research grade pH meter replacement probe specially designed to respond quickly and accurately to rapid temperature changes. The high sensitivity internals also make these electrodes the best choice for low ionic samples. The double junction reference design prevents contamination, allowing pH testing in samples containing heavy metals, proteins and enzymes, or TRIS buffer.
  • Our most sensitive laboratory electrode: accurate to 0.04 pH in tests across full recommended temperature range
  • Easily maximize measurement repeatability: Rapid renew reference system for quick refilling
  • Extensive chemical compatibility: Constructed with durable Ultem®, proven in a range of chemical conditions
  • Ideal for difficult sample types: Double junction reference protection for testing samples containing heavy metals, TRIS buffer, and other contaminants
  • Virtually unbreakable: removable bulb guard protects pH glass and strain relief prevents damage to cable connection
  • Ready for wet or corrosive environments: BNC boot protects meter connection
  • Compatible with various meters: Versatile replacement probe works with any meter accepting a BNC pH probe
Recommended for: Low ionic samples, medical and pharmaceutical research, biological samples, samples containing heavy metals
Quick View

DioSense

Key Benefits
The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.
  • Amperometric sensors – continuous online chlorine dioxide ppm measurement
  • No chemical reagents – lower cost of ownership
  • Stable and reliable – excellent process control
  • Suitable for all potable and process waters
  • Up to 6 months between maintenance
  • No interference from residual chlorine (DioSense M)
  • Tolerant of water containing detergents
  • Up to 70°C (DioSense NM)
  • Up to 6 Bar (DioSense NM)
Back to top