Product Information
Category: Water Quality Monitoring SystemsProduct Description
Applications such as environmental and wastewater sampling involve some uncertainty about what samples may contain. When dealing with unknown or unpredictable sample types, you need a durable pH probe you can trust to deliver accurate measurements regardless of the contaminants you encounter. The pH2000 has a double junction reference design to prevent reference fouling by heavy metals and other sample contaminants. When you travel to remote sites to collect data, it is especially important that obtaining the measurements you need is hassle free. The pH2000 features an Ultem® body and a booted meter connection for durability in the field. The sealed reference design requires no maintenance. Compatible with any meter accepting a BNC connector.
- Durable and low maintenance: Ultem® body construction, reinforced meter connection, and sealed reference design
- Great for testing unknown sample types: Double junction reference protection prevents reference cell contamination
- Accurate measurements across full pH scale (0-14)
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- Compatible with any meter accepting a BNC connector
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
Related Products
HaloSense Zero
Key Benefits
Many water companies want to measure free chlorine residuals without the need for chemical buffers traditionally associated with such measurements. Acetate and phosphate buffers are expensive and environmentally unfriendly. Buffer delivery systems are maintenance intensive and have fairly costly consumables and there are health and safety considerations in the handling of the acids and high disposal costs if the acid treated water is unable to be fed back into the water supply. Amperometric cells and most polarographic probes only respond to hypochlorous acid, (HOCl). HOCl dissociates into hypochlorite (OCl–) in a pH dependent manner. This is why most chlorine monitors need acid buffers in most applications. The typical pH of water measured on a water treatment works may range from 7 to 9.2. Chemical buffering reduces the pH to between 5 and 6 and ensures that the majority of the residual chlorine is present as HOCl (see graph below).- Low purchase cost
- Low cost of ownership
- Reduced pH dependency (largely pH independent)
- Stable and reliable
- Bufferless
- Reagentless
PC-100 pH/ORP Panel Meter
Applications
Water treatment Pure water System Clean room Wastewater treatment Scrubber Electronics processFeatures
- 48 x 96 mm Microprocessor pH/ORP Monitor & Controller
- Sensor slope performance diagnosis & error message
- User-friendly operation
- Automatic temperature compensation
- Compatible with Pt-1000 and NTC 30K temperature probe
- Isolated current output DC 0/4~20mA
- Gradually continuous sample measurements average function to enhance stability
BioSense
Key Benefits
The BioSense range of qualitative biofouling monitors provide a relative measure of "activity" of biofilm being present in your process, allowing you to dose your biocide accordingly or take other appropriate remidial action.- Legionella control
- Automatic Biocide control
- Can be combined with other sensors
- No maintenance
- Cooling towers and any water circuit
- Seawater option Reduced chemical costs Up to 10 Bar
FluoriSense
Key Benefits
Pi’s FluoriSense range of fluoride monitors and fluoride analyzers utilize the very latest and best fluoride sensors available in the world today for measuring the online fluoride content of any potable water. They are ion selective electrodes (ISEs) with integral reference, automatic temperature compensation and solid polymeric junction. which use no reagents, are extremely stable, and have reduced maintenance and reduced whole life costs.- Measuring method: ISE (Ion Specific Electrode)
- Measure range: 0.02 ppm saturation
- Sample pH range: 5 to 7 pH at 1 x 10⁻⁶ M / 5 to 11 pH at saturation
- Temperature range: 0 to 80°C continuous / 80 to 100°C intermittent
- Electrode resistance: less than 50 MΩ
- Reproducibility: ±2%
- Cable length: 100cm
- Calibration: Manual using test kit
- No reagent required
OzoSense
Key Benefits
- Stable and reliable – excellent ozone process control – ozone controllers
- Suitable for all potable, process and salt waters – ozone monitor – ozone analyzer
- Up to 6 months between maintenance
- Up to 3 months between calibration
- Does not respond to residual chlorine (OzoSense M)
- Resistant to detergents in the water
- Up to 70°C (OzoSense NM)
- Onboard PID controls – dissolved ozone Controller
- Onboard data logging and graphing capability
- Onboard comms such as TCP/IP, Modbus, Profibus and more.
PC-3100 Series Microprocessor pH/ORP Transmitter
Robust protection and precise integration
The PC-3100 series pH/ORP transmitter has rugged IP 65 enclosure and can be wall, panel, pipe mounted for installation in almost any industrial application. The PC-3100RS offers RS-485 interface to support digital communication to your PLC. The transmitters inherit our reliable technology which features in accurate, robust, and easy to use functions.
Applications
Water treatment Chemical process Biochemical process Wastewater treatment Electrical process Food and beverage processFeatures
- pH, ORP, Temperature measurement
- IP 65 waterproof and dustproof design
- Back-lit LCD with ON/OFF/Auto programmable illumination
- Two sets of isolated current output DC 0/4~20mA corresponding to measurement and temperature
- Two Hi/Lo Limited contact outputs; Set points with programmable hysteresis function
- Automatic temperature compensation
- Gradually continuous sample measurements average function to enhance stability
- Wash function with programmable time-interval control
- LED indication alarm or wash status signal
- Password protection
- PC-3100RS with one analog output and one RS-485 interface
pH2200 Spear Tip Plastic pH Sensor
Product Description
Looking to measure the pH of soil, meat, or cheese? A standard pH sensor with bulb shaped glass won’t effectively pierce the surface of these semi-solids; the pH glass may even crack. That’s why we’ve created the pH2200 spear tip pH sensor, specially designed to penetrate semi-solid surfaces for effective pH measurement. The sensor is assembled with a bio-friendly Ultem® body, making it safe for use in food and soil. Use this durable pH sensor at home or in the field with any pH meter accepting a BNC connector.- Rugged spear tip measurement surface for piercing semi-solid samples
- Bio-friendly Ultem® body for safe measurements in food and soil
- Long-lasting with built-in protection against protein contamination
- No refilling or maintenance required with sealed gel-filled design
- Instantly ready for use and shipped in storage bottle for long shelf life
ORP1000 Polycarbonate Laboratory ORP Sensor
Product Description
The ORP1000 is a durable and easy to use ORP sensor. Great for outdoor applications, such as monitoring swimming pool chlorine, this probe has built in protection for the ORP sensor surface. Use the ORP1000 with any ORP meter accepting a BNC connector.- Very fast response time: Platinum measurement surface for fast response time and stable readings
- No maintenance required: Sealed reference design requires no refilling
- Durable construction: Polycarbonate body is built for frequent lab or field use
- Instantly ready for use: Shipped in storage bottle for long shelf life – guaranteed for one year
- One year limited warranty: We stand behind all our products with the Sensorex Guarantee
DioSense
Key Benefits
The DioSense chlorine dioxide measurement sensors and flow cells are available with different controllers giving you the same great performance with different communication, display, and chlorine dioxide dosing control options. The two controllers offer different options but both offer the same great user interface and Pi’s great quality.- Amperometric sensors – continuous online chlorine dioxide ppm measurement
- No chemical reagents – lower cost of ownership
- Stable and reliable – excellent process control
- Suitable for all potable and process waters
- Up to 6 months between maintenance
- No interference from residual chlorine (DioSense M)
- Tolerant of water containing detergents
- Up to 70°C (DioSense NM)
- Up to 6 Bar (DioSense NM)
SoliSense®
Key Benefits
- From 2 NTU to 8% Solids
- Displays in NTU, mg/l, g/l or % solids – flexible
- Auto-clean optical sensor – months without maintenance
- Stable and reliable – excellent process control
- Suitable for all potable, waste and process waters
- Up to 12 months between maintenance
- Up to 12 months between calibration
- Less spares – more commonality across a single or multiple sites
- No requirement to know the range prior to specifying – easier purchasing
- One online suspended solids analyzer can be:
- Online mlss meter
- Online tss meter
- Online total suspended solids meter
- Online effluent monitor
- Online inlet monitor
- Online ‘in process’ suspended solids analyzer